Built-in hobs
Only use the built-in hobs after you assemble the hob into correct built-in units and work
surfaces that align to the standards.
Connection cable
The hob is supplied with a connection cable.
For a single-phase connection use the cable types: H03BB-F, H03V2V2-F or H03VV-F,
which withstand the temperature of 70°C or higher, or the cable types suitable for a two-
phase connection.
For a two-phase connection use the cable types: H05BB-F, H05V2V2-F or H05VV-F
which withstand the temperature of 70°C or higher.
Assembly
min.
50mm
min.
500mm
R 5mm
min.
55mm
490
+1
mm
750
+1
mm
min.
28 mm
min.
12 mm
min.
20 mm